Skip to main content

Proxmox RAID Setup

Requirements / Prerequisites

  • At least 2 SSD/HDDs of the same model. This must have the same capacity. Models with different revisions are usually okay.
  • A Proxmox installation on at least one of the SSD/HDDs.

Introduction

As of Proxmox 7.2, this does not natively support RAID drive configurations through the main setup wizard. As a result, RAID needs to be setup either before or after a Proxmox installation.

For details on how to set this up before Proxmox, Debian must be setup on the RAID configuration before installation. (See Install Proxmox VE on Debian 11 Bullseye)

In this guide, we will walkthrough how to setup RAID after a Proxmox installation on a single drive.

Environment Example

  • /dev/sda is the drive Proxmox has been installed onto.
  • /dev/sda1 is the BIOS partition
  • /dev/sda2 is the boot partition
  • /dev/sda3 is the Proxmox OS partition
  • /dev/sdb is the identical drive that contains no data.

Walkthrough

  1. Proxmox uses a base Debian installation. mdadm must be installed for Software RAID to be handled by the kernel module. An apt-update must also be run if this is freshly installed.
apt update && apt install mdadm
  1. Using sfdisk, we can extract the current partition configuration from the drive. We use grep and sed to filter out any labels/UUIDs that are specific to the /dev/sda drive. The partition table is applied to the new drive (/dev/sdb).
sfdisk -d /dev/sda > part_table
grep -v ^label-id part_table | sed -e 's/, *uuid=[0-9A-F-]*//' | sfdisk /dev/sdb
  1. With mdadm, we can create a new RAID device in a degraded state. We first attach the new empty drive partition (/dev/sdb3).
mdadm --create /dev/md0 --level 1 --raid-devices 2 /dev/sdb3 missing
  1. Using LVM, we create an LVM Physical Volume(PV) and add to existing Volume Group(VG). /dev/pve is the virtual device created by the Proxmox setup via LVM.
pvcreate /dev/md0
vgextend /dev/pve /dev/md0
  1. Using LVM tools again, we move data from the original drive (/dev/sda3) to the new virtual RAID device (/dev/md0).
pvmove /dev/sda3 /dev/md0
caution

Note that step 5 will take a while to process, even with an SSD. Allow this step to complete successfully before proceeding.

  1. Now we remove the original drive from the LVM VG (/dev/pve). Remember that dev/sdb3 is also now backing this VG.
vgreduce /dev/pve /dev/sda3
  1. Add /dev/sda3 to /dev/md0 to start resyncing the RAID array.
mdadm --manage --add /dev/md0 /dev/sda3
  1. Use dd to byte copy EFI and BIOS boot partitions to the new drive.
dd if=/dev/sda1 of=/dev/sdb1
dd if=/dev/sda2 of=/dev/sdb2
  1. Install GRUB on all disks. This also adds entries in the UEFI boot options.
grub-install /dev/sda
grub-install /dev/sdb
  1. This updates initramfs to support new drive layout
update-initramfs -u -k all
  1. Wait for RAID-1 sync to finish
watch cat /proc/mdstat

Verification

At the end of this walkthrough, your drive configuration should be similar to this:

# lsblk
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
sda 8:96 0 465.8G 0 disk
├─sda1 8:97 0 1007K 0 part
├─sda2 8:98 0 512M 0 part /boot/efi
└─sda3 8:99 0 465.3G 0 part
└─md0 9:0 0 465.1G 0 raid1
├─pve-swap 253:0 0 8G 0 lvm [SWAP]
├─pve-root 253:1 0 96G 0 lvm /
├─pve-data_tmeta 253:2 0 3.5G 0 lvm
│ └─pve-data 253:4 0 338.4G 0 lvm
└─pve-data_tdata 253:3 0 338.4G 0 lvm
└─pve-data 253:4 0 338.4G 0 lvm
sdb 8:112 0 465.8G 0 disk
├─sdb1 8:113 0 1007K 0 part
├─sdb2 8:114 0 512M 0 part
└─sdb3 8:115 0 465.3G 0 part
└─md0 9:0 0 465.1G 0 raid1
├─pve-swap 253:0 0 8G 0 lvm [SWAP]
├─pve-root 253:1 0 96G 0 lvm /
├─pve-data_tmeta 253:2 0 3.5G 0 lvm
│ └─pve-data 253:4 0 338.4G 0 lvm
└─pve-data_tdata 253:3 0 338.4G 0 lvm
└─pve-data 253:4 0 338.4G 0 lvm
[... Other entries omitted for brevity ...]

mdadm should start automatically syncing. This is what it should look like after a successful resync.

# watch cat /proc/mdstat
Every 2.0s: cat /proc/mdstat

Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10]
md0 : active raid1 sda3[2] sdb3[0]
487729152 blocks super 1.2 [2/2] [UU]
bitmap: 1/4 pages [4KB], 65536KB chunk

unused devices: <none>

Additional Notes

  • You can probably apply this setup to the boot partiation as well, however this has not been tested yet.
  • If a hard drive is replaced, you must manually copy the data from the first two partitions manually. When the drive is added back to the RAID array, mdadm should take care of the resyncing of data again.